Single-phase watt-hour meter.
Three-phase multifunctional watt-hour meter.
Ultra-thin single-phase watt-hour meter YTGP-1.
Provides 5+2 clear LCD display.
Accuracy Class 1.
Optional pulse output.
Three-phase watt-hour meter, YTGP-3(4) provides 6+1.
Clear LCD character display. Accuracy Class 1.
Pulse output. 35mm rail mounting. RS485 communication.
Single-phase multifunctional watt-hour meter.
Three-phase multifunctional watt-hour meter (CT).
Ultra-thin single-phase exquisite watt-hour meter YTGP-1(TA). Provides 6+1 clear large-character LCD display. Accuracy Class 1. Pulse output. Mounted on 35mm rail. RS485 communication.
Three-phase watt-hour meter YTGP-3(4)(TA). Provides 6+1 clear large-character LCD display. Accuracy Class 1. CT connection mode. Pulse output. Mounted on 35mm rail. RS485 communication.
performance parameter | |
start | Under the conditions of rated voltage, rated power and cos φ = 1, when the load current of the watt-hour meter is the value specified in the table below, the watt-hour meter should have a pulse output and continuously record the point energy |
insulation performance | All the lines of the watt-hour meter can withstand a pulse voltage with a waveform of 1.2/50 uS and a peak value of 6KV between the metal parts accessible to the outside of the case. Under different models, each continuous experiment is 10 times, and there is no arc discharge or breakdown phenomenon. All the lines of the watt-hour meter can withstand the AC voltage of the actual sine wave with a frequency of 50HZ between the case or the outside of the case 2KV, and the experiment lasts for one minute without breakdown |
dive | With anti-submersion design; when the current line of the watt-hour meter is at noon and the voltage applied to the voltage line is 115% of the rated, the test output of the watt-hour meter within the specified time should not generate more than one pulse |
power consumption | Power consumption (voltage line: < 2W and 10VA); with automatic identification function of electric current direction. |
(Voltage line) | The reverse electrical energy has been metered in the total amount of electricity. |
Limit operating voltage | Operating voltage limit: 70~ 130% Ub |
Maximum short circuit current | Maximum short-term current: 30 times the maximum current for 10ms (50HZ) |
working environment | Use at ambient temperature -20 ° C to 55 ° C, relative humidity not exceeding 85% (without condensation) |
error value | |||
current value | power factor cosφ=1 | percentage error limit(%) | |
direct access | Transformer access | Level 1 | |
0.05lb | 0.02lb | 1 | ±1.5 |
0.1lb | 0.05lb | 0.5L | ±1.5 |
0.8C | ±1.5 | ||
0.1lb~1max | 0.05lb~1max | 1 | ±1.0 |
0.2b~1max | 0.1lb~1max | 0.5L | ±1.0 |
0.8C | ±1.0 |
Product Specifications | |||||||
name | Model | accuracy | Rated voltage (Ub) | Rated current(A) | starting current | outputoutput | communication |
Single phase energy meter | Level 1 | AC220±20% | 5(30)A | 0.4%lb | pulse | none | |
Single phase energy meter | Level 1 | AC220±20% | 5(80)A | 0.4%lb | pulse | Optional RS485 | |
Three-phase energy meter | Level 1 | 3×AC220/AC380±20% | 10(100)A | 0.4%lb | pulse | Optional RS485 | |
Three-phase energy meter | Level 1 | 3×AC220/AC380±20% | 5A | 0.4%lb | pulse | Optional RS485 |
Typical wiring diagram | |
Single phase energy meter | |
Single-phase multi-energy energy meter | |
Three-phase multi-function energy meter | |
Three-phase multi-function energy meter CT |